The stress of the components was evaluated under maximum-load and maximum-displacement conditions to ensure that yield does not occur. |
Cross-feed Flexure |
Carraige Flexure |
Leadscrew Flexure |
|
|
|
|
The frequency of vibration of the components was determined to prevent resonance with common noise sources such as the 60 Hz AC power supply. |
|
Mode 1 - 131 Hz |
Mode 2 - 139 Hz |
Mode 3 - 141 Hz |
|